  1. Path: quasar.xs4all.nl!ekrieger
  2. Subject: Re: Termination problems
  3. Newsgroups: comp.sys.amiga.hardware
  4. References: <haraldk.55.31208F19@sofus.hiof.no> <4g1ugb$m6r@newsbf02.news.aol.com>
  5. X-Newsreader: TIN [AMIGA 1.3 950726BETA PL0]
  6. From: ekrieger@quasar.xs4all.nl (Eric Krieger)
  7. Message-ID: <ekrieger.1yrd@quasar.xs4all.nl>
  8. Date: Sun, 25 Feb 96 14:06:08 +0100
  9. Organization: Private, Delft [NL]
  10.  
  11. DJM2984712 (djm2984712@aol.com) wrote (on 16 Feb 1996 07:49:15 -0500):
  12.  
  13. > In article <haraldk.55.31208F19@sofus.hiof.no>, haraldk@sofus.hiof.no
  14. > (Harald Kuhr) writes:
  15.  
  16. > >Could annyone help him finding the correct jumpers for termination
  17. > >and/or some documentation for the drive?
  18.  
  19. Jumpers for the LPS105S:
  20.  
  21.  SS = Self Seek Test   (Off = Disabled <default>)
  22.                        (On  = Self Seek Enabled (For factory use only!)
  23.  EP = Partity Checking (Off = Disabled)
  24.                        (On  = Enabled. Drive generates parity info and
  25.                               performs partity checking of data across the
  26.                               SCSI-bus <default>).
  27.  WS = Wait Spin        (Off = Drive motor power is applied when system-
  28.                               power is applied to the computer <default>).
  29.                        (On  = Enabled. Drive motor power is applied when
  30.                               the host sends a START/STOP UNIT command.)
  31.  A0 = Off \
  32.  A1 = On   > SCSI-ID. Default = 6 (A1 and A2 jumpered)
  33.  A2 = On  /
  34.  
  35.  SCSI-ID   A0  A1  A2
  36.    0       Off Off Off
  37.    1       On  Off Off
  38.    2       Off On  Off
  39.    3       On  On  Off
  40.    4       Off Off On
  41.    5       On  Off On
  42.    6       Off On  On
  43.    7       On  On  On
  44.  
  45. Termination of the drive is determined by whether the resistor-pack
  46. network terminator are mounted/inserted or not (either 2 or 3 packs
  47. just behind the 50 pins SCSI-connector.
  48.  
  49.  
  50. Whenever you have addional questions or need additional information,
  51. I would advise you to look at the www page of quantum:
  52.  
  53. http://www.quantum.com
  54.  
  55.  
  56. > You can call Quantum's Fax Back service at 1-800-4DISKFAX.  Order
  57. > their catalog, find the ID of the drive you need info on, & they'll
  58. > fax you the spec sheet.
  59.  
  60. This is not possible for people living outside the USA (Harald seems
  61. to live in Norway, which is in Europe), since 1-800 numbers are only
  62. available to USA-citizens!  Please remember this next time! Thank you.
  63.  
  64. BTW. Harald asked to sent the replies by Email to someone else (i.e.
  65.      no follow-up in the newsgroup).
  66.  
  67. -- 
  68. |  Eric Krieger  :  ekrieger@quasar.xs4all.nl   |  Fido-Net: 2:285/1.10  |
  69. |   Q U A S A R  :  Last Point of Endless Time  |  AmigaNet: 39:102/1.21 |
  70.